BHVLD - ERSIN 5381 FLUX TYPE RMA

  • MSDS: BHVLD
  • Manufacturer: MULTICORE SOLDERS INC
  • Product Name: ERSIN 5381 FLUX TYPE RMA
  • National Stock Number: 3439-00N010971
Product Identification

Product ID:ERSIN 5381 FLUX TYPE RMA
MSDS Date:09/02/1986
FSC:3439
NIIN:00N010971
MSDS Number: BHVLD

Responsible Party
MULTICORE SOLDERS,INC
CANTIAGUE ROCK ROAD
WESTBURY, NY 11590

Emergency Phone: 214-238-1224;516-334-7997

Info Phone: 516-334-7997

Cage: 03051

Contractor
MULTICORE SOLDERS
WESTBURY, NY 11590 US

Telephone: 214-238-1224

Cage: 03051

Ingredients

METHYL ALCOHOL (METHANOL) (SARA III)

CAS: 67-56-1

RTECS: PC1400000

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192


ROSIN.MAY DECOMPOSE DURING SOLDERING TO EMIT FORMALDEHYDE

CAS: 8050-09-7

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:UNKNOWN Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
OVEREXPOSURE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:LIQ/VAP CONT CAN CAUSE
IRRIT.SKIN:PRLNG/RPTD CONT CAN CAUSE DRYNESS & IRRIT.INGEST:MAY
CAUSE MARKED & PERSISTENT NAUS,VOMIT,ABDOM PAIN.INHAL:HIGH VAP CONC
CAN IRRIT RESP TRACT,MAY CAUSE BRONCHOPN EUMONIA/PULMONARY
EDEMA.EFTS OF
OVEREXPOS:IRRITATION,HEADACHE,DIZZINESS,NAUSEA,INCOORD,DROWSINESS,L
OSS OF CONSCIOUSNESS.
Medical Cond Aggravated by Exposure:NONE PRESENTLY KNOWN.

First Aid

First Aid:EYES:FLUSH WITH WATER FOR AT LEAST 15 MINUTES.GET MEDICAL
ATTENTION.SKIN:WASH WITH SOAP AND WATER.INGESTION:INDUCE VOMITING
BY TOUCHING FINGER TO BACK OF THROAT.KEEP VICTIM'S HEAD BELOW HIPS
WHILE VOM ITING.GET MEDICAL ATTENTION.INHALATION:REMOVE VICTIM TO
FRESH AIR.GIVE ARTIFICIAL RESPIRATION IF NOT BREATHING.GET MEDICAL
ATTENTION.

Fire Fighting

Flash Point Method:TCC
Flash Point:62F,16.67C
Lower Limits:12%
Upper Limits:2.5%
Extinguishing Media:CARBON DIOXIDE,ALCOHOL RESISTANT FOAM,DRY CHEMICAL
POWDER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .EVACUATE UNPROTECTED PERSONNEL FROM HAZARD
AREA.
Unusual Fire/Explosion Hazard:NO UNUSUAL HAZARDS.HAZARDOUS
DECOMPOSITION PRODUCTS:CARBON MONOXIDE,CARBON DIOXIDE.

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES.HANDLING
EQUIPMENT MUST BE GROUNDED TO PREVENT SPARKING.EVACUATE THE HAZARD
AREA OF UNPROTECTED PERSONNEL.ABSORB SPILLED MATERIAL W/ AN
ABSORBENT MATERIAL AND PLACE IN N ON-LEAKING CONTAINER.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT,SPARKS,AND OPEN
FLAMES.KEEP CONTAINERS TIGHTLY CLOSED.GROUND ALL HANDLING
EQUIPMENT.
Other Precautions:MINIMIZE SKIN CONTACT.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:NEOPRENE OR RUBBER.
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:WEAR PROTECTIVE CLOTHING TO PREVENT SKIN
CONTACT.
Work Hygienic Practices:WASH WITH SOAP AND WATER BEFORE
EATING,DRINKING,SMOKING,OR USING TOILET FACILITIES.
Supplemental Safety and Health
BP RANGE:149-180F,65-82.22C.VP:33 MMHG AT 68C,154.4F.ROUTES OF
ENTRY:INHALATION,INGESTION .

Chemical Properties

Boiling Pt:B.P. Text:SEE SUPP
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:SEE SUPP
Vapor Density:2.07,AIR=1
Spec Gravity:0.887 (WATER=1)
Evaporation Rate & Reference:1.7 (BUTYL ACETATE=1)
Solubility in Water:PARTIALLY SOLUBLE
Appearance and Odor:LIGHT AMBER LIQUID WITH ALCOHOLIC SMELL.
Percent Volatiles by Volume:65

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Stability Condition to Avoid:AVOID HEAT,SPARKS,OPEN FLAMES.
Hazardous Decomposition Products:CARBON MONOXIDE,CARBON DIOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .PLACE IN A DISPOSAL FACILITY
APPROVED UNDER RCRA REGULATIONS FOR HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.